NT8D15 E&M Trunk card Page 641 of 894

Table 198

Electrical characteristics of trunk cards (Part 2 of 2)

Characteristic

DID Trunk

CO trunk

 

 

 

Signaling type

Loop

Ground or loop start

Far-end battery

-42 to -52.5 V

-42 to -52.5 V

Near-end battery

N/A

-42.75 to -52.5 V

Minimum loop current

N/A

20 mA

Ground potential difference

+ 10 V

+ 3 V

Low DC loop resistance

N/A

300 ohms

during outpulsing

 

 

High DC loop resistance

N/A

Ground start equal to or

 

 

greater than 30 kS. Loop start

 

 

equal to or greater than 5 MS

Line leakage

Equal to or greater than 30

 

kS (Tip to Ring, Tip to GND,

 

Ring to GND).

Effective loss

See pad table

Equal to or greater than 30 kS (Tip to Ring, Tip to GND, Ring to GND)

See pad table

Power requirements

Table 199 lists the power requirements for the E&M trunk card.

Table 199

Power requirements

Voltage

Tolerance

Max current

 

 

 

+15.0 V dc

±5%

200 mA

–15.0 V dc

±5%

200 mA

+8.5 V dc

±2%

200 mA

–48.0 V dc

±5 %

415 mA

 

 

 

Circuit Card Description and Installation

Page 641
Image 641
Nortel Networks 553-3001-211 manual Lists the power requirements for the E&M trunk card