Page 506 of 894 NT7D16 Data Access card

required. The defaults are bracketed, and may be issued by Carriage Return (<CR>).

LD 11 – Configure Data Access card. (Part 1 of 3)

Prompt

Response

Description

 

 

 

REQ:

NEW CHG MOV

Add, change, move or copy the unit

 

COPY

 

TYPE:

R232

RS-232-C unit

 

R422

RS-422 unit

TN

l s c u

DAC data TN. The loop (LL) must be a superloop.

RNPG

<CR>

Ringing number pickup group (default to zero)

CLS

 

Class of Service allowed for the DAC.

 

DTA

Data Allowed

 

ADD

Digit Display Allowed

TOV

(0) - 3

Timeout value, where:

 

 

0 = no timeout

 

 

1 = 15 minutes

 

 

2 = 30 minutes

 

 

3 = 60 minutes

OPE

(NO) YES

Operation parameter change

PAR

(SPAC) ODD EVEN

SPAC = space parity

 

MARK

ODD = odd parity

 

 

EVEN = even parity

 

 

MARK = mark parity

DTR

(OFF) ON

DTR settings, where:

 

 

ON = forced DTR

 

 

OFF = dynamic DTR

 

 

This prompt appears only if TYPE = R232

 

 

 

553-3001-211 Standard 2.00 September 2004

Page 506
Image 506
Nortel Networks 553-3001-211 manual Prompt Response Description