NT5D97 Dual-port DTI2/PRI2 card Page 351 of 894

Case 3 - The network shelf is full, one port of a QPC414 network card is connected to a digital trunk, and the second is connected to a peripheral buffer. This arrangement is repeated for another QPC414. The digital trunks are located in a shelf that provides only power.

In this case, the peripheral buffers will have to be re-assigned, so that each pair of buffers will use both ports of the same QPC414 card. The other QPC414 card can then be replaced by the NT5D97 DDP2.

CAUTION

The static discharge bracelet located inside the cabinet must be worn before handling circuit cards. Failure to wear the bracelet can result in damage to the circuit cards.

Procedure 14

Installing the NT5D97

1Determine the cabinet and shelf location where the NT5D97 is to be installed. The NT5D97 can be installed in any card slot in the Network bus.

2Unpack and inspect the NT5D97and cables.

3If a DDCH is installed, refer to the section “Removing the NT5D97” on page 352.

4Set the option switches on the NT5D97 card before installation. Refer to “NT5D97AA/AB DIP switch settings” on page 328.

The ENB/DIS (enable/disable faceplate switch) must be OFF (DIS) when installing the NT5D97, otherwise a system initialize can occur. The ENB/ DIS on the NT5D97 corresponds to the faceplate switch on the QPC414 Network card.

5Install NT5D97 card in the assigned shelf and slot.

6Set the ENB/DIS faceplate switch to ON.

If the DDCH is installed, the DDCH LED should flash three times.

7If required, install the I/O adapters in the I/O panel.

Circuit Card Description and Installation

Page 351
Image 351
Nortel Networks 553-3001-211 manual Procedure Installing the NT5D97