Page 198 of 894 NT5D11 and NT5D14 Lineside T1 Interface cards

Table 77

Lineside T1 card – T1 Switch 2 (S2) dip switch settings (Part 2 of 2)

Dip Switch

 

 

Number

Characteristic

Selection

 

 

 

7

Daisy-chaining to MMI

On = Yes

 

 

Off = No

8

MMI Master or Slave

On = Master

 

 

Off = Slave

 

 

 

Table 78

Lineside T1 card – CPE or CSU distance dip switch settings (Switch S2, positions 3 – 5)

 

S2 Switch

S2 Switch

S2 Switch

Distance

Position 3

Position 4

Position 5

 

 

 

 

0–133

On

Off

Off

134–266

Off

On

On

267–399

Off

On

Off

400–533

Off

Off

On

534–655

Off

Off

Off

 

 

 

 

Installation

This section describes how to install and test the lineside T1 card.

When installed, the lineside T1 card occupies two card slots. It can be installed into an NT8D37 IPE module.

When installing the lineside T1 card into NT8D37 IPE module, determine the vintage level module. If the 25-pair I/O connectors are partially split between adjacent IPE card slots, the lineside T1 card works only in card slots where Unit 0 of the motherboard card slot appears on the first pair of the 25-pair I/ O connector.

553-3001-211 Standard 2.00 September 2004

Page 198
Image 198
Nortel Networks 553-3001-211 manual 198 of 894 NT5D11 and NT5D14 Lineside T1 Interface cards