Page 292 of 894 NT5D33 and NT5D34 Lineside E1 Interface cards

Figure 51

Display Status (D S) screen

LEI

S/N

 

Software Version 1.01

3/03/95

1:50

 

In alarm state:

NO

 

 

 

 

 

E1 link

at

alarm

level

0

 

 

 

 

Port

0

off

hook,

Port 1 on hook, Port 2 on

hook, Port 3 on hook,

Port

4

on hook, Port 5

on hook, Port 6 off

hook, Port 7 off

hook,

Port

8

off

hook,

Port 9 on hook, Port 10 on hook, Port 11 on hook,

Port

12

off hook, Port

13

on hook, Port 14

on hook, Port 15

on hook,

Port

16

on

hook,

Port 17 on hook, Port 18 off hook, Port 19

off hook,

Port

20

off hook, Port

21

on hook, Port 22

on hook, Port 23

on hook

Port

21

off hook, Port

22

on hook, Port 23

on hook, Port 24

on hook,

Port

25

on

hook,

Port 26 on hook, Port 27 off hook, Port 28

off hook,

Port

29

off hook

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Performance counters and reporting

The MMI monitors the performance of the E1 link according to several performance criteria including errored, bursty, unavailable, loss-of-frame and frame-slip seconds. It registers the performance of these criteria by reading their status every second and counting their results. These counts are accumulated for an hour, then reset to 0. Previous hour count results are maintained for each of the previous 24 hours.

The LEI counts CRC-4 errors when CRC-4 is enabled and Bipolar Violations (BPV) when CRC-4 is disabled. The performance criteria for which these counts are maintained as follows:

Errored seconds are seconds in which one or more CRC-4 / BPV errors, or one or more out-of-frame errors in one second.

Bursty seconds are seconds in which more than one and less than 320 CRC-4 / BPV errors in a second.

Severely errored seconds are seconds in which more than

320 CRC-4 / BPV errors, or one or more out-of-frames in a second.

Unavailable seconds are seconds in which unavailable state starts with 10 consecutive severely errored seconds and ends with 10 consecutive non-severely errored seconds (excluding the final 10 non-severely errored seconds).