Table 107 indicates how the RR control signal operates with regard to the DDP2 status.

Table 107

DCH/MSDL Receiver Ready control signals

RR State

Condition

 

 

ON

D-Channel data rate selected at 64 Kbps

 

and

 

PRI2 loop is enabled

 

and

 

PRI2 link is not in OOS or Local Alarm mode state

 

and

 

PRI2 link is not transmitting a Remote Alarm pattern

 

and

 

PRI2 link is not receiving a Remote Alarm Indication

 

from a remote facility

OFF

All other conditions

 

 

NT5D97 faceplate

Figure 62 on page 310 illustrates the faceplate layout for the NT5D97 DDP card. The faceplate contains an enable/disable switch; a DDCH status LED; 6 x 2 trunk port status LEDs; and six external connectors. Table 108 on page 311 shows the name of each connector, its designation with respect to the faceplate and the name and description of the card it is connected to. Also shown are the names of the LEDs.