QPC513 Enhanced Serial Data Interface card

Page 853 of 894

 

 

 

 

 

 

 

Table 266

 

 

 

 

 

ESDI card DTE/DCE mode jumper settings

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Jumper socket

 

Mode

Port

 

designations

 

 

 

 

 

 

 

Data communication equipment (DTE)

1

 

UA10

UA12

 

Data terminal equipment (DCE)

1

 

UA9

UA11

 

 

 

 

 

 

 

Data communication equipment (DTE)

2

 

UA17

UA19

 

Data terminal equipment (DCE)

2

 

UA16

UA18

 

 

 

 

 

 

 

Table 267

 

 

 

 

 

ESDI card RS-232-C/high-speed interface jumper settings

 

 

 

 

 

 

 

 

 

 

 

Jumper socket

 

Mode

Port

 

designations

 

 

 

 

 

 

 

RS-232-C interface

1

 

UB9

UB11

 

High-speed interface

1

 

UB10

UB12

 

 

 

 

 

 

 

RS-232-C interface

2

 

UB16

UB18

 

High-speed interface

2

 

UB17

UB19

 

 

 

 

 

 

Software service changes

All of the other ESDI port operating parameters are defined in software and downloaded to the assigned ESDI port. See Table 261 on page 843. These changes are made using the Configuration Record program (LD 17). Instructions for the Configuration Record program are found in the Software Input/Output: Administration (553-3001-311).

Some of the prompts that are commonly used when running the Configuration Record program (LD 17) are shown in LD 17 – Serial port configuration

Circuit Card Description and Installation

Page 853
Image 853
Nortel Networks 553-3001-211 manual Esdi card DTE/DCE mode jumper settings, Mode Port Designations, UA9, UB9