QPC513 Enhanced Serial Data Interface card Page 853 of 894
Circuit Card Description and Installation
Software service changes
All of the other ESDI port operating parameters are defined in software and
downloaded to the assigned ESDI port. See Table 261 on page 843. These
changes are made using the Configuration Record program (LD 17).
Instructions for the Configuration Record program are found in the Software
Input/Output: Administration (553-3001-311).
Some of the prompts that are commonly used when running the Configuration
Record program (LD 17) are shown in LD 17 – Serial port configuration
Table 266
ESDI card DTE/DCE mode jumper settings
Mode Port
Jumper socket
designations
Data communication equipment (DTE) 1 UA10 UA12
Data terminal equipment (DCE) 1 UA9 UA11
Data communication equipment (DTE) 2 UA17 UA19
Data terminal equipment (DCE) 2 UA16 UA18
Table 267
ESDI card RS-232-C/high-speed interface jumper settings
Mode Port
Jumper socket
designations
RS-232-C interface 1 UB9 UB11
High-speed interface 1 UB10 UB12
RS-232-C interface 2 UB16 UB18
High-speed interface 2 UB17 UB19