NT5D11 and NT5D14 Lineside T1 Interface cards Page 223 of 894

When entering the Set Alarm command set, the MMI will scroll through the previously described series of alarm options. These options are displayed along with their current value. Enter a new value or press Enter to retain the current value. Table 85 outlines the options available in the Set Alarm function.

Table 85

Set alarm options

Option

Description

 

 

AL1 Threshold

Sets the allowable bit errors per second (from 3 to 9) before alarm

 

level 1 is activated. Factory default is 10–6.

AL1 Duration

Sets the duration in seconds (from 1 to 3,600 seconds) that alarm

 

level 1 is activated. Factory default is 10 seconds.

AL2 Threshold

Sets the allowable bit errors per second (from 3 to 9) before alarm

 

level 2 is activated. Factory default is 10-5.

AL2 Duration

Sets the duration in seconds (from 1 to 3,600 seconds) that alarm

 

level 2 is activated. Factory default is 10 seconds.

Frame Slip Threshold

Sets the allowable frame slips per time period (from 1 to 255) before

 

alarm level 2 is activated. Factory default is 5.

Frame Slip Duration

Sets the duration in hours (from 1 to 24) that the frame slips are

 

counted. After this time period, the counter is reset to 0. Factory default

 

is 2 hours.

 

 

 

Note: If the duration period is set too long, the lineside T1 card will be

 

slow to return to service automatically even when the carrier is no longer

 

experiencing any errors. The Clear Alarm command will have to be

 

entered manually to restore service promptly. To avoid this, the duration

 

period should normally be set to 10 seconds.

Set Clearing

Use the Set Clearing (S C) command set to enable or disable alarm self-clearing. Answer Y or N to the question: “Enable Self Clearing? (YES or NO)”. If “Enable Self-Clearing” is chosen (the factory default condition), the system will automatically clear alarms after the alarm condition is no longer detected for the corresponding duration period.