Overview Page 63 of 894

The switch communicates with IPE modules over two separate interfaces. Voice and signaling data are sent and received over DS-30X loops and maintenance data is sent over a separate asynchronous communication link called the card LAN link.

Signaling data is information directly related to the operation of the telephone line. Some examples of signaling commands are as follows:

off hook/on hook

ringing signal on/off

message waiting lamp on/off

Maintenance data is data relating to the setup and operation of the IPE card, and is carried on the card LAN link. Some examples of maintenance data are as follows:

polling

reporting of self-test status

CPU initiated card reset

reporting of card ID (card type and hardware vintage)

reporting of firmware version

downloading trunk interface unit configuration

reporting of trunk interface unit configuration

enabling/disabling of the DS-30X network loop bus

reporting of card status

Circuit Card Description and Installation

Page 63
Image 63