Page 282 of 894 NT5D33 and NT5D34 Lineside E1 Interface cards

Table 102

Set alarm options (Part 2 of 2)

Option

Description

 

 

AL2 Threshold

Sets the allowable bit errors per second (from 3 to

 

9) before alarm level 2 is activated. Factory

 

default is 10-5.

 

 

AL2 Duration

Sets the duration in seconds (from 1 to 3,600

 

seconds) that alarm level 2 is activated. Factory

 

default is 10 seconds.

 

 

Frame Slip

Sets the allowable frame slips per time period

Threshold

(from 1 to 255) before alarm level 2 is activated.

 

Factory default is 5.

 

 

Frame Slip Duration

Sets the duration in hours (from 1 to 24) that the

 

frame slips are counted. After this time period, the

 

counter is reset to 0. Factory default is 2 hours.

 

 

Note: If the duration period set is too long, the LEI card is slow to return to service automatically even when the carrier is no longer experiencing errors. The CLEAR ALARM (C A) command has to be entered manually to restore service promptly. To avoid this, an alarm’s duration period is normally set to 10 seconds.

Set Clearing

The SET CLEARING (S C) command allows self-clearing of alarms by responding to the question: Enable Self Clearing? (YES or NO). If YES is chosen (the factory default setting), the system automatically clears (resets) alarms after the alarm condition is no longer detected. Choosing the NO option causes the system to continue the alarm condition until the Clear Alarm (C A) command is entered. Line processing and yellow alarm indication to the CPE terminates as soon as the alarm condition clears, even if self-clearing is disabled.

Set Simple

The SET SIMPLE command controls call tear-down signaling when the far-end disconnects from a call.

553-3001-211 Standard 2.00 September 2004

Page 282
Image 282
Nortel Networks 553-3001-211 manual Set alarm options Part 2, Set Simple