NT8D14 Universal Trunk card Page 609 of 894

Table 188

Trunk types – termination impedance and balance network (NT8D14BA, NT8D14BB)

 

Terminating

Balance network for loop lengths (Note 2)

 

 

 

 

 

 

 

 

Trunk types

impedance

0–915 m

915–1524 m

> 1524 m

(Note 1)

(0–3000 ft)

(3000–5000 ft)

(> 5000 ft)

 

 

 

 

 

 

CO/FX/WATS

600 or 900

600 ohms

3COM

3CM2

 

ohms

 

 

 

 

 

 

 

 

2-way TIE (LDR)

600 or 900

600 ohms

3COM

3CM2

 

ohms

 

 

 

 

 

 

 

 

2-way TIE

600 or 900

600 ohms

3COM

3CM2

(OAID)

ohms

 

 

 

 

 

 

 

 

DID (loop length

600 or 900

600 ohms

3COM

3CM2

< 600 ohms)

ohms

 

 

 

 

 

 

 

 

DID (loop length

600 or 900

600 ohms

N/A

3CM2

Š 600 ohms)

ohms

 

 

 

 

 

 

 

 

RAN: continuous

600 or 900

600 or 900 ohms

N/A

N/A

operation mode

ohms

 

 

 

 

 

 

 

 

Paging

600 ohms

600 ohms

N/A

N/A

 

 

 

 

 

Note 1: The terminating impedance of each trunk unit is software selectable in LD 14 and should match the nominal impedance of the connecting equipment.

Note 2: The balance network of each trunk unit is software selectable between resistive 600 or 900 ohms or 3COM and jumper selectable between 3COM and 3CM2. Jumper selection for 3COM/3CM2 restriction does not apply to NT8D14BB.