NT6D42 Ringing Generator DC

Tables 21 through 26 list option settings for the NT6D42 Ringing Generator.

Table 21

NT6D42 recommended options for North American and British Telecom

 

Ringing

Ringing

 

 

Application

frequency

voltage

Jumper locations

Ringing output

 

 

 

 

 

North America

20 Hz

86 V ac

P5

Low impedance

 

 

 

High voltage

 

 

 

 

message waiting

 

British Telecom

25 Hz

80 V ac

P4

Low impedance

 

 

 

No high voltage

 

 

 

 

message waiting

 

 

 

 

 

 

Table 22

NT6D42 jumper locations P4 and P5

High voltage message waiting

Pin location

 

 

Disable

Jumper in P4

Enable

Jumper in P5

 

 

Note: One jumper must be installed.

 

 

 

Table 23

 

NT6D42 jumper location J7

 

 

 

Ringing output

Jumper location J7

 

 

Low impedance (normal)

Connect pins 1 and 2

High impedance (Australia)

Connect pins 2 and 3

 

 

553-3001-211 Standard 2.00 September 2004

Page 112