NTDK20 Small System Controller card Page 805 of 894

Table 254

Expansion daughterboards

 

 

 

Max. distance between Call

 

Number

 

Server and MG 1000S

Daughterboard

of ports

Cable type

systems

 

 

 

 

NTDK99 (used in

one

Use the supplied

MG 1000S systems can be

MG 1000S)

 

NTTK34AA UTP CAT 5

located up to 100 m (328 ft.)

 

 

RJ-45 2 m cross-over

from the Call Server if

NTDK83 (used in

two

cable to connect the

connected point-to-point, or

Call Server

 

 

Call Server and

up to 40 km (24 miles) from

 

 

 

 

MG 1000S using the

the Call Server if a third party

 

 

100BaseT

converter is used to convert to

 

 

daughterboards.

fiber.

 

 

The NTTK34AA

 

 

 

cross-over cable must

 

 

 

be used if connecting

 

 

 

point-to-point.

 

 

 

 

 

Note: If not connecting point-to-point, connect the Call Server and

MG 1000S using a straight-through Ethernet UTP Cat 5 cable.

Call Servers can be connected to MG 1000S systems in the following ways:

Use 100BaseT to connect to the LAN for voice distribution over a data network.

Use 100BaseT cable if connected point-to-point (directly) to the

MG 1000S. The NTTK34AA crossover cable must be used. MG 1000S systems can be located up to 100 meters from the Call Server.

Use Media Conversion devices (third party converters) to convert 100BaseT to fiber for distances from 100 m to 40 km.

See Figure 170 on page 806.

Circuit Card Description and Installation

Page 805
Image 805
Nortel Networks 553-3001-211 manual NTTK34AA UTP CAT