Page 276 of 894 NT5D33 and NT5D34 Lineside E1 Interface cards

Each of these commands can be executed by entering the first letter of the command or by entering the entire command. Commands with more than one word are entered by entering the first letter of the first word, a space, and the first letter of the second word or by entering the entire command. Table 100 shows all possible MMI commands in alphabetical order. These commands are also described later in this section.

Table 100

MMI commands and command sets (Part 1 of 2)

Command

Description

 

 

A D

Alarm Disable. Disables all alarms.

A E

Alarm Enable. Enables all alarms.

C A

Clear Alarm. Clears all alarms, terminates time processing, and resets

 

the E1 bit error rate and frame slip counters.

C A L

Clear Alarm Log. Clears alarm log.

C E

Clear Error. Clears the E1 error counter.

D A(P)

Display Alarms. Displays the alarm log, which is a list of the 100 most

 

recent alarms with time and date stamps. (Momentarily stop the

 

scrolling display by typing P. Continue scrolling by typing any other

 

key.)

D C(P)

Display Configuration. Displays the configuration settings for the

 

LEI(s), single- or multiple-card system. Display includes each card’s

 

serial number, MMI firmware version, date and time, alarm

 

disable/enable setting, self-clearing disable/enable setting, values

 

entered through the Set Configuration command, and dip switch

 

settings.(Momentarily stop the scrolling display by typing P. Continue

 

scrolling by typing any other key.)

D H(P)

Display History. Displays performance counters for the past 24 hours.

 

(Momentarily stop the scrolling display by typing P. Continue scrolling

 

by typing any other key.)

D P

Display Performance. Displays performance counters for the current

 

hour.

 

 