NTAK79 2.0 Mb PRI card Page 735 of 894

 

 

 

Table 234

 

 

NTAK79 LEDs (Part 2 of 3)

 

 

 

 

LED

State

Definition

 

 

 

RED

On (Red)

A red alarm state has been detected. This represents

 

 

a local alarm state of:

 

 

Loss of Carrier (LOS)

 

 

Loss of Frame (LFAS), or

 

 

Loss of CRC Multiframe (LMAS).

 

 

 

 

Off

No red (local) alarm.

 

 

 

YEL

On (Yellow)

A yellow alarm state has been detected. This

 

 

represents a remote alarm indication from the far

 

 

end. The alarm can be either Alarm Indication (AIS)

 

 

or Remote Alarm (RAI).

 

 

 

 

Off

No yellow (remote) alarm.

 

 

 

LBK

On (Green)

2 MB PRI is in loop-back mode.

 

 

 

 

Off

2 MB PRI is not in loop-back mode.

 

 

 

CC

On (Red)

The clock controller is switched on and has been

 

 

disabled by the software.

 

 

 

 

On (Green)

The clock controller is switched on and is either

 

 

locked to a reference or in free run mode.

 

 

 

 

Flashing (Green)

The clock controller is switched on and attempting to

 

 

lock on to a reference (tracking mode). If the LED

 

 

flashes continuously over an extended period of

 

 

time, check the CC STAT in LD 60. If the CC is

 

 

tracking this can be an acceptable state. Check for

 

 

slips and related clock controller error conditions. If

 

 

none exist, then this state is acceptable, and the

 

 

flashing is identifying jitter on the reference.

 

 

 

Circuit Card Description and Installation

Page 735
Image 735
Nortel Networks 553-3001-211 manual NTAK79 LEDs Part 2, Red