NTCK16 Generic Central Office Trunk cards Page 797 of 894

Therefore the following steps must be followed when the Generic XFCOT is installed:

1Define Loss Switching mode. Respond to the prompts in LD 97 as shown.

LD 97 – Defining Loss Switching mode.

Prompt

Response

Description

 

 

 

REQ:

CHG

 

TYPE:

SYSP

IPE system parameters configuration

...

 

 

NATP

YES

Select North American transmission plan.

 

 

Note: The default to the NATP prompt is NO, and

 

 

therefore this prompt must always be checked during

 

 

installation.

 

 

 

2Define Loss Switching Class Of Service. Respond to the prompts in LD 14 as shown.

LD 14 – Defining Loss Switching Class Of Service.

Prompt

Response

Description

 

 

 

REQ:

CHG

 

TYPE:

COT

 

XTRK

XCOT

 

SIGL

LOP

 

...

 

 

CLS

LOL

LOL= Long Line

 

 

Note: The XFCOT uses the CLS Long Line (LOL) and

 

 

Short Line (SHL) for Loss Switching purposes and that

 

 

the card and trunk type is different from the XUT.

 

 

 