Page 660 of 894 NT8D41AA Serial Data Interface Paddle Board

Table 206

Connectors J1 and J2 pin assignments (Part 2 of 2)

Pin #

Signal

Purpose in DTE mode

Purpose in DCE mode

 

 

 

 

8

CTS

Clear to send (Note 1)

Clear to send

 

 

 

 

Note 1: In DTE mode the signals CD, DSR, and CTS are tied to +12 volts to signify that the port on the SDI paddle board is always ready to transmit and receive data.

Note 2: In DCE mode the signals DTR and RTS are tied to +12 volts to signify that the port on the SDI paddle board is always ready to transmit and receive data.

Configuring the SDI paddle board

Configuring the SDI paddle board consists of setting these option switches for each serial port:

Port address

Baud rate

DTE/DCE/Fiber mode

The SDI paddle board has seven option switches, SW 2–8. Figure 156 on page 664 identifies the location of option switches on the SDI paddle board. Instructions for setting these switches are in the section that follows.

Once the board has been installed, the system software must be configured to recognize it. Instructions for doing this are found in “Software service changes” on page 665.

553-3001-211 Standard 2.00 September 2004

Page 660
Image 660
Nortel Networks 553-3001-211 manual Configuring the SDI paddle board, Cts, Clear to send Note