Page 482 of 894 NT7D16 Data Access card

Table 157

Hayes parameters and S register reset values (Part 2 of 2)

Parameter

Value

Description

 

 

 

V

1

Result codes sent in Verbose format

X

1

Features selection 0 - 8, 10 - 13

P

Dial method (pulse)

S0

0 *?1

Manual Answer (if 0)?Auto answer on 1 ring

S1

0

Ring count 0

S2

43

Escape sequence character Plus sign (+)

S3

13

Terminator character Carriage Return (<CR>)

S4

10

New line character Line Feed (<LF>)

S5

8

Back space character BS (<BS>)

S6

2

Blind dial delay 2 seconds

S7

30

Timeout for outbound call answer 30 seconds

S8

2

Dial pause delay 2 seconds

S9

6

Carrier detect response time 0.6 seconds

S10

14

Call disconnect timer for carrier loss 1.4 seconds

S11

95

Touchtone space 95 milliseconds

S12

50

Escape sequence guard timer 1.00 seconds

*Parameters that are reset to the downloaded operating parameters when 1 is entered at the reset command.

553-3001-211 Standard 2.00 September 2004

Page 482
Image 482