NT5D97 Dual-port DTI2/PRI2 card Page 353 of 894

3If the NT5D97 card is being completely removed, not replaced, remove data from memory.

4Remove cross connections at MDF to wall-mounted cross-connect terminal.

5Tag and disconnect cables from card.

6Rearrange Clock Controller cables if required.

CAUTION

Clock Controller cables connecting the Clock Controller and DDP2 card must NOT be routed through the center of the cabinet past the power harness. Instead, they should be routed around the outside of the equipment shelves.

7Remove the DDP2 card only if both loops are disabled. If the other circuit of a DDP2 card is in use, DO NOT remove the card. The faceplate switch ENB/DIS must be in the OFF (DIS) position before the card is removed, otherwise the system will initialize.

8Pack and store the NT5D97 card and circuit card.

End of Procedure

Configuring the NT5D97

After the NT5D97 DDP2 is installed, configure the system using the same procedures as the standard NT8D72BA PRI2.

Consider the following when configuring the NT5D97 DDP2 card:

The CS 1000 Release 4.0 software allows four ports to be defined for the NT6D80 MSDL. The DDCH (NTBK51AA) card has only two ports, 0 and 1; therefore, ports 2 and 3 must not be defined when using the NTBK51AA.

Circuit Card Description and Installation

Page 353
Image 353
Nortel Networks 553-3001-211 manual Configuring the NT5D97, End of Procedure