Page 598 of 894 NT8D14 Universal Trunk card

Table 180

Universal trunk card – trunk interface electrical characteristics (Part 2 of 2)

 

 

Trunk Types

 

 

 

 

 

 

Characteristic

CO / FX / WATS

DID / TIE

RAN

Paging

 

 

 

 

 

Ring detection

17 to 33 Hz

N/A

N/A

N/A

 

40 to 120 V rms

 

 

 

 

 

 

 

 

Line leakage

Š 30k ohms,

Š 30k ohms,

N/A

N/A

 

tip-to-ring,

tip-to-ring,

 

 

 

tip-to-ground,

 

 

 

tip-to-ground,

 

 

 

ring-to-ground

 

 

 

ring-to-ground

 

 

 

 

 

 

 

 

 

 

 

AC induction

10 V rms, tip-to-ring,

10 V rms, tip-to-ring,

N/A

N/A

rejection

tip-to-ground,

tip-to-ground,

 

 

 

ring-to-ground

 

 

 

ring-to-ground

 

 

 

 

 

 

 

 

 

 

 

Selected in software.

 

 

 

 

Selected by jumper strap settings on card. Refer to Tables 185, 186, and 187 for details.

For loop extender application, the maximum voltage applied between tip and ring is –105 V ±5%. The minimum dc loop resistance for this type of application is 1800 ohms.

Power requirements

Power to the NT8D14 Universal Trunk card is provided by the module power supply (ac or dc).

Table 181

Power requirements for universal trunk card

Voltage

Tolerance

Current (max.)

 

 

 

+15.0 V dc

+5%

306 mA

 

 

 

–15.0 V dc

+5%

306 mA

 

 

 

+5.0 V dc

+5%

750 mA

 

 

 

+8.5 V dc

+2%

450 mA

 

 

 

–48.0 V dc

+5%

415 mA

 

 

 