Page 712 of 894 NTAK10 2.0 Mb DTI card

Card-LAN for maintenance communication

per-channel and all-channel loopback capabilities for near-end and far-end

self-test

download of incoming ABCD validation times from software

warm SYSLOAD (TS16 AS16 transmitted)

Applicability to France

Features specific to DTI requirements for France are implemented in firmware, and are switch-accessed. These are:

transmission and reception of alarm indication signaling (AIS) in TS16 such as card disabled and warm SYSLOAD

France-specific PPM counting

decadic dialing

France-specific alarm report and error handling

Architecture

The main functional blocks of the NTAK10 card architecture include:

DS-30X interface

signaling interface

three microprocessors

digital pad

Card-LAN interface

carrier interface

clock controller interface

DS-30X interface

The NTAK10 card interfaces to one DS-30X bus which contains

32 byte-interleaved timeslots operating at 2.56 Mb. Each timeslot contains

553-3001-211 Standard 2.00 September 2004

Page 712
Image 712
Nortel Networks 553-3001-211 manual DS-30X interface, Applicability to France