Page 104 of 894 Option settings

Table 13

OPS analog line card configuration (Part 3 of 3)

Application

On-premise station (ONS)

 

 

Off-premise station (OPS)

 

 

 

 

 

 

 

Class of Service

 

ONP

 

 

 

OPX

(CLS) (Note 1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BIMP

600

3COM1

3COM2

 

600

 

3COM1

3COM2

3COM2

(Notes 1, 4)

ohms

 

 

 

ohms

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gain treatment

 

 

 

No

 

 

 

Yes

(Note 5)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note 1: Configured in the Analog (500/2500-type) Telephone Administration program (LD 10).

Note 2: The maximum signaling range supported by the OPS analog line card is 2300 ohms.

Note 3: Loss of untreated (no gain devices) metallic line facility. Upper loss limits correspond to loop resistance ranges for 26 AWG wire.

Note 4: Default software impedance settings are:

 

ONP CLS

OPX CLS

TIMP:

600 ohms

600 ohms

BIMP:

600 ohms

3COM2

Note: Gain treatment, such as a voice frequency repeater (VFR) is required to limit the actual OPS loop loss to 4.5 dB, maximum. VFR treatment of metallic loops having untreated loss greater than 15 dB (equivalent to a maximum signaling range of 2300 ohms on 26 AWG wire) is not recommended.

Note: Jumper strap settings JX.0 and JX.1 apply to all eight units; “X” indicates the unit number, 0–7. “Off” indicates that a jumper strap is not installed across both pins on a jumper block. Store unused straps on the OPS analog line card by installing them on a single jumper pin as shown below:

Jumper pin

Jumper strap

Jumper block

553-5924

553-3001-211 Standard 2.00 September 2004