Page 740 of 894 NTAK79 2.0 Mb PRI card

monitoring of receive carrier alarms including AIS, LOS, and RAI

transmission of remote alarm when instructed

slip-buffering receive messages

supporting National and International bits in time slot 0

on-board clock controller

onboard D-channel interface

32 software-selectable Tx & Rx Pad values

conversion of PCM commanding Laws (A-A, u-u, A-u, u-A)

Card-LAN for maintenance communication

Architecture

The main functional blocks of the NTAK79 architecture include:

DS-30X interface

A07 signaling interface

digital pad

carrier interface

CEPT transceiver

SLIP control

D-channel support interface

8031 microcontroller

Card-LAN / echo / test port interface

DS-30X interface

The NTAK79 interfaces to one DS-30X bus which contains 32 byte-interleaved timeslots operating at 2.56 Mb. Each timeslot contains

10 bits in A10 message format; eight are assigned to voice/data (64 kbps), one to signaling (8 kbps), and one is a data valid bit (8 kbps).

553-3001-211 Standard 2.00 September 2004

Page 740
Image 740
Nortel Networks 553-3001-211 manual 740 of 894 NTAK79 2.0 Mb PRI card