Option settings Page 141 of 894

QPC528 CO/FX/WATS Trunk cards

Table 49 lists switch and jumper settings for options available.

Table 49

QPC528 Trunk cards switch and jumper settings

Switch Settings

 

Switch S1 (location A23)

 

 

 

 

 

 

 

Switch position:

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

4

 

5

 

6

7

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

on

off

on

off

 

on

 

off

on

off

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Unit 0, Switch S2 (Location E29)

 

 

 

 

 

 

Unit 1, Switch S3 (Location E9)

 

 

 

 

 

 

Unit 2, Switch S4 (Location A28)

 

 

 

 

 

Switch position:

Unit 3, Switch S5 (Location A10)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

4

 

5

 

6

7

8

9

10

 

 

 

 

 

 

 

 

 

 

 

 

 

Trunk type:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Loop start

off

on

off

off

 

on

 

off

 

 

off

off

 

 

 

 

 

 

 

 

 

 

 

 

 

Ground start

off

on

on

on

 

on

 

off

 

 

off

off

 

 

 

 

 

 

 

 

 

 

 

 

 

Metering:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Second pair (M, MM) or

 

 

 

 

 

 

 

 

off

off

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Third wire, battery on M or

 

 

 

 

 

 

 

 

off

on

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Third wire, ground on M

 

 

 

 

 

 

 

 

on

off

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Jumper Settings

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Unit 0 jumper (Location E27)

 

 

 

 

 

 

Unit 1 jumper (Location E11)

 

 

 

 

 

 

Unit 2 jumper (Location D29)

 

 

 

 

 

 

Unit 3 jumper (Location D9)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Jumper:

Unit 0

Unit 1

 

Unit 2

Unit 3

 

 

 

Jumper

Jumper

 

Jumper

Jumper

 

 

 

 

 

 

 

 

 

 

600 ¾ resistive impedance

Pin 1 to 2

Pin 1 to 2

 

Pin 1 to 2

Pin 1 to 2

 

 

 

 

 

 

 

 

 

 

3-component complex

Pin 2 to 3

Pin 2 to 3

 

Pin 2 to 3

Pin 2 to 3

 

 

impedance

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Circuit Card Description and Installation

Page 141
Image 141
Nortel Networks 553-3001-211 manual QPC528 CO/FX/WATS Trunk cards, Lists switch and jumper settings for options available