Page 480 of 894 NT7D16 Data Access card

Table 156

Allowable S registers (Part 2 of 2)

S register

Range

Range units

Supported

Description

 

 

 

 

 

S8

0–30

Seconds

Yes

Duration for the dial pause

 

 

 

 

character

S9

1–255

0.1 second

No

Carrier detect response time

S10

1–255

0.1 second

No

Delay time between loss of carrier

 

 

 

 

and call release

S11

50–255

Milliseconds

No

Touch tone spacing

S12

20–255

20 milliseconds

Yes

Guard time for the escape

 

 

 

 

sequence

 

 

 

 

 

You can view any of the S registers by issuing the following display command. Any S register can be specified through the ATS command, and the system will display the current setting for that parameter. More than one S register can be viewed by listing the desired registers on the same command line.

One register

Two registers

ATS8?

ATS8? S9

20

002

OK

006

 

OK

To change any S register range, except S1, use the following change command. The new parameters remain in effect until another change command is given or the Hayes Reset modem command (Z) is issued. If the DAC is powered up, the parameters are reset to the defaults.

ATS8 = 15

OK

553-3001-211 Standard 2.00 September 2004

Page 480
Image 480
Nortel Networks 553-3001-211 manual ATS8?