Page 844 of 894 QPC513 Enhanced Serial Data Interface card

Table 261

Characteristics of synchronous ports (Part 2 of 2)

Characteristics

Description

 

 

Data Link Level LAPB protocol remote

(3), 1

host address

 

Modify link control system parameters*

yes, (no)

Modify link performance thresholds

yes, (no)

(Note 1)

 

 

 

Note 1: * See the Configuration Record (LD 17) in Software Input/Output: Administration (553-3001-311) to modify the link control system parameters and performance thresholds.

Note 2: The values in parentheses are the default.

Clock timing option

The ESDI card offers two timing options:

Internal: The ESDI card uses an internal timing source to synchronize data transfers to the external device.

External: The ESDI card accepts a timing source from the high-speed interface connector to synchronize data transfers to the external device.

Test and maintenance features

The ESDI card has these built-in testing and maintenance capabilities:

Self-test

The ESDI card performs a self-test of its major components immediately after power-up. The self-test can also be initiated through the Link Diagnostic program LD 48. The self-test tests all ESDI functions up to, but not including, the ESDI line drivers and receivers.

553-3001-211 Standard 2.00 September 2004

Page 844
Image 844
Nortel Networks 553-3001-211 manual Clock timing option, Test and maintenance features, Self-test