Page 30 of 894 Overview

configure the card according to instructions issued by the system

report back to the system information such as card identification (type, vintage, and serial number), firmware version, and programmed configuration status)

Table 2

IPE module architecture

Parameter

IPE

 

 

Card Dimensions

31.75 x 25.4 x 2.2 cm.

 

(12.5 x10.0 x 0.875 in.)

 

 

Network Interface

DS-30X Loops

 

 

Communication Interface

card LAN Link

 

 

Microcontroller

8031 / 8051 Family

 

 

Peripheral

NT8D01 Controller card

Interface card

 

 

 

Network Interface card

NT8D04 Superloop Network card

 

 

Modules

NT8D37 IPE module

 

 

Intelligent Peripheral Equipment

IPE line cards all have a similar architecture. Figure 2 on page 32 shows a typical IPE line card architecture. The various line cards differ only in the number and types of line interface units.

The switch communicates with IPE modules over two separate interfaces. Voice and signaling data are sent and received over DS-30X loops, and maintenance data is sent over a separate asynchronous communication link called the card LAN link.

Signaling data is information directly related to the operation of the telephone line. Some examples of signaling commands include:

off-hook/on-hook