Acceptance tests Page 95 of 894

When you see the DN? prompt, enter the directory number (DN) you want the system to dial.

If the system response is other than OK, see the Software Input/Output:

Administration (553-3001-311) to analyze the messages.

4End the session in LD 36:

****

5Test an automatically identified outward dialing (AIOD) trunk card:

LD 41

AIOD l s c loop, shelf, and card numbers

If the system response is other than OK, see the Software Input/Output: Administration (553-3001-311) to analyze the messages.

6End the session in LD 41:

****

End of Procedure

Tone and digit switch cards

Procedure 10

Testing tone and digit switch cards

Use this procedure to test a tone and digit switch (TDS) card or to test the TDS function of an NT8D17 Conference/TDS card.

1Log into the system: LOGI (password)

2Obtain a list of terminal numbers (TNs) for disabled TDS cards:

LD 34 STAD

3If the TDS loop to be tested is disabled, enable it.

For an NT8D17 Conference/TDS card, enter:

ENLX loop

(the TDS/MFS loop is the even loop of the conference/TDS loop pair)

Note: The conference/TDS card is not enabled automatically when it is inserted. You must enable the card with the command ENLX. (This command is used in LD 34 and LD 46 to address even loops and in LD 38 to address odd loops.) Enabling the loops with the command ENLL does not enable the hardware for the card.

Circuit Card Description and Installation

Page 95
Image 95