NTCK16 Generic Central Office Trunk cards Page 789 of 894

NTCK16AX Central Office trunk card

Route Data Block

Respond to the prompts in LD 16 as shown.

LD 16 – Route Data Block for NTCK16AX.

Prompt

Response

Description

 

 

 

REQ:

NEW

Define a new unit

TYPE:

COT

Define a new Route Data Block

CUST

xx

Customer number as defined in LD 15.

ROUT

 

Route number

 

0-511

Range for Large System, Call Server 1000E,

 

 

and Media Gateway 1000E

 

0-127

Range for Small System, CS 1000S system,

 

 

Media Gateway 1000B, and

 

 

Media Gateway 1000T

TKTP

COT

Define trunk type as Central Office

ICOG

IAO

Incoming and Outgoing trunk

CNTL

YES

Change a trunk timer

TIMER

RGV 256

Set Ring Validation Timer to 128 ms.

MR

(NO) PPM XLD

PPM is off, buffered, or unbuffered on this route.

 

 

 

Circuit Card Description and Installation

Page 789
Image 789
Nortel Networks 553-3001-211 manual NTCK16AX Central Office trunk card, Route Data Block