Acceptance tests Page 93 of 894

Multifrequency signaling cards

Procedure 6

Testing multifrequency signaling cards

Use this procedure to test a multifrequency signaling card.

1Log into the system: LOGI (password)

2Test and enable the specified unit:

LD 54

ATST l s c u loop, shelf, card, and unit numbers

If the system response is other than OK, see the Software Input/

Output: Administration (553-3001-311) to analyze the messages.

3End the session in LD 54:

****

End of Procedure

Network cards

Procedure 7

Testing network cards

Use this procedure to test a network card.

1Log into the system: LOGI (password)

2Perform a network memory test, continuity test, and signaling test:

LD 30

LOOP loop can be a specific loop number or ALL

If ALL is specified, all enabled loops (except attendant console loops) and all shelves on each loop are tested.

If only one loop is being tested and it is disabled, enter ENLL loop to enable and test a network card associated with the specified loop. (This command cannot enable network cards disabled by LD 32.)

If the system response is other than OK, see the Software Input/Output: Administration (553-3001-311) to analyze the messages.

Circuit Card Description and Installation

Page 93
Image 93
Nortel Networks 553-3001-211 manual Multifrequency signaling cards, Network cards, Procedure Testing network cards