NT7D16 Data Access card Page 427 of 894

Table 152

DAC mode of operation selection (Part 4 of 5)

Service changeable downloadable parameters (LD 11)

Operation mode

Modem/

Gateway/

Host/KBD

Forced

DTR*

Hotline

Type of device to be connected

Group selection

DEM

PRM

DTR

HOT

10 (DCE)

OFF

ON

OFF

Host similar to

Modes 8, 9, 10,

 

“Host On”

Forced

Not

MCDS but does not

and 11 are for

 

(prompts

 

Hotline

require DTR to be

RS232 Host

 

off)

 

 

ON

connectivity

11 (DCE)

OFF

ON

On

Continuous Hotline

 

 

“Host On”

Forced

Hotline

mode when DTR is

 

 

(prompts

 

 

ON (VLL)

 

 

off)

 

 

 

 

12 (DCE)

ON

OFF

OFF

Terminal similar to

Modes 12 and 13

 

“KBD On”

Not

Not

Asynchronous/

are for RS422

 

(prompts

Forced

Hotline

Synchronous

Terminal

 

on)

 

 

Interface Module

connectivity

 

 

 

 

(ASIM) when set to

 

 

 

 

 

Not Forced DTR

 

 

 

 

 

and Not Hotline

 

 

 

 

 

Prompt PBDO =

 

 

 

 

 

OFF/ON

 

13 (DCE)

ON

OFF

On

Terminal similar to

 

 

“KBD On”

Not

Hotline

ASIM when set to

 

 

(prompts

Forced

 

Not Forced DTR

 

 

on)

 

 

and Hotline

 

* Not prompted for Type = R422. Defaults for Type = R422: DEM = DCE and DTR = OFF.

Circuit Card Description and Installation

Page 427
Image 427
Nortel Networks 553-3001-211 manual On VLL