Graco 313289s important safety instructions Replace Alarm, Display, Upgrade Software

Models: 313289s

1 86
Download 86 pages 37.45 Kb
Page 35
Image 35

Replace Alarm

1.Remove shroud. See Remove Shroud.

2.Disconnect power.

3.Remove four nuts (4); leave two nuts on left side of panel tight. Open front panel of control box (11).

4.Disconnect alarm wires from alarm (217).

5.Unscrew alarm (217) and replace.

r_312359_313289_22

217

6.Screw in new alarm. Reconnect alarm wires. Refer to Electrical Schematics, page 47.

7.Reassemble air control front shroud (12).

Display

Upgrade Software

Do not upgrade software when an explosive gas atmo- sphere may be present.

NOTICE

To avoid damaging circuit board, wear a grounding strap.

Use software token 16A265. See Graco Control Archi- tectureModule Programming manual for instructions.

Repair

NOTE: Upgrade all modules in the system to the software version on the token, even if you are replacing only one or two modules. Different soft- ware versions may not be compatible.

All data in the module may be reset to factory default settings. Record all settings and user prefer- ences before the upgrade, for ease of restoring them following the upgrade.

The latest software version for each system can be found at Tech Support at www.graco.com.

1.Remove shroud. See Remove Shroud.

2.Disconnect power.

3.Remove four nuts (4); leave two nuts on left side of panel tight. Open front panel of control box (11).

4.Remove four screws (204f) and then access cover (204e).

204f

Battery

L

204e

T

r_xm1a00_312359_313289_2a

5. Insert and press token (T) firmly into slot.

NOTE:

There is no preferred orientation of token.

6.Turn power on.

7.The red indicator light (L) will flash until new soft- ware is completely loaded.

8.Turn power off.

9.Remove token (T).

10.Reassemble access cover (204e) and screws (204f).

313289S

35

Page 35
Image 35
Graco 313289s important safety instructions Replace Alarm, Display, Upgrade Software