Repair

Fluid Control Assembly

6.Remove dosing valves. See manual 313342 for dosing valve service and repair instructions.

7.Follow steps in reverse order to reassemble dosing valve assembly.

Dosing Valve Assembly

1.Follow Pressure Relief Procedure, page 12.

2.Disconnect all fluid lines from dosing valve assem- bly (8).

3.Remove three bolts (16) on back of each dosing valve (501) from bracket.

4.Unscrew dosing valve housing seats from adapters on mix manifold.

r_312359_313289_40

Housing

Seat

Adapter

5.Disconnect RTD (506) from cord grip. Disconnect pressure sensor (507) and fluid line adapter from each dosing valve (501).

501Fluid Line

Adapter

Bracket

16

506

ti21278a

Mix Manifold Assembly

1.Follow Pressure Relief Procedure, page 12.

2.Disconnect fluid line and solvent lines from mix manifold assembly.

3.Loosen four bolts securing mix manifold (508) to bracket.

39

508

313289_

Bracket

r 312359

 

Bolts

Bolts

4.Unscrew dosing valve housing seats from adapters on mix manifold.

5.Remove four bolts securing mix manifold (508) to bracket.

6.Remove mix manifold assembly (508) from bracket. See manual 312749 for mix manifold service and repair instructions.

7.Follow steps in reverse order to reassemble mix

manifold assembly.

42

313289S

Page 42
Image 42
Graco 313289s important safety instructions Fluid Control Assembly, Dosing Valve Assembly, Mix Manifold Assembly