Troubleshooting

Troubleshooting

NOTE:

If an error code displays, see Alarms on page 23.

NOTE:

The sprayer operates using air pressure. Many prob- lems are caused by inadequate air supply. The inlet air pressure gauge cannot drop below 50 psi (0.35 MPa, 3.5 bar) while running.

Problem

Cause

Solution

 

 

 

 

 

 

Display not lit on system with alternator

Air valve not turned on.

Turn on main air valve to system.

power supply.

 

 

Air supply pressure too low.

Increase pressure to 30 psi (0.21 MPa,

 

No electric power.

 

2.1 bar) or greater.

 

 

 

 

Air supply filters plugged. Inlet manifold

Clean filter bowls; replace filter elements.

 

filter (604) or air regulator (344) filter

Page 31.

 

plugged.

 

 

 

 

 

Turbine air regulator (277) set too low.

Adjust to 18 +/- 1 psi (12.6 +/- 10 kPa,

 

 

1.26 +/- 0.07 bar).

 

 

 

 

Alternator turbine failure.

Repair or replace turbine. Page 38.

 

 

 

 

Power supply not connected to main

Check power connections to main board.

 

board.

See Electrical Schematics, starting on

 

 

page 47.

 

 

 

 

Display board failure.

Replace display board. Page 36.

 

 

 

Display not lit on system with alternator

Faulty CAN cable (268). Or CAN cable is

Check cable and replace. See Alternator

power. Green light is present on FCM

disconnected.

Assembly, page 72.

(218) and USB (219), but no green light is

 

 

Faulty display module.

Replace display module. See User Inter-

present on back of display module (204).

 

face/Control Box, page 32.

 

 

 

 

 

Display not lit on system with wall power

No electric power. Disconnect “off” or

Reset main disconnect and breaker.

supply. No green light present on back of

breaker “open.”

 

display module (204).

 

 

No green lights present on display, FCM,

Check for 24 Vdc on J1, pins 2 and 3, of

 

 

or USB module.

power supply. See Electrical Schemat-

 

 

ics, starting on page 47. If there is not 24

 

 

Vdc, replace with 15V747.

 

 

 

 

No display power through CAN cable

Check CAN cable. Replace if necessary.

 

(266). Green light in present on FCM

See Wall Power Supply Assembly,

 

(218), but is not present on USB module

page 73.

 

(219).

 

 

 

 

 

Green light is present on USB module

Check CAN cable (274). Replace if nec-

 

(219).

essary. See Wall Power Supply Assem-

 

 

bly, page 73.

 

 

 

Display not lit on system with wall power

Display module failed.

Replace display module. See User Inter-

supply. Green light is present on back of

 

face/Control Box, page 32.

display module (204).

 

 

 

 

 

20