Before Repair
313289S 11
Before Repair

Location

Grounding

Connect ground wire clamp (FG) to a true earth ground.
If wall power is used to power controls or heaters,
ground electrical connection properly according to local
codes.

Proper Lifting of Sprayer

Lift Using a Forklift

Power must be off. Sprayer can be raised and moved
using a forklift. Carefully lift the sprayer; make sure it
balances evenly.

Lift Using a Hoist

Sprayer can also be lifted and moved using a hoist.
Connect a bridle swing, hooking an end to each of the
air motor lift rings. Hook the center ring to a hoist Care-
fully lift the sprayer; make sure it balances evenly.
XM sprayers are not approved for use in hazardous
locations unless the base model, all accessories, all
kits, and all wiring meet local, state, and national
codes. See Models, page 7, to determine the appro-
priate location for your particular model.
FG
ti21273a
Follow instructions to avoid serious injury or damage
to equipment. Never lift with the hopper(s) filled.
2.0 ft. (0.61 m)
minimum
ti21274a