Alarms

Alarm

 

 

 

 

Code

Alarm Problem

When Active

Cause

Solution

 

 

 

 

 

 

 

 

 

 

 

 

Optional User-Settable Spray Limits

 

T5A

Temperature exceeded alarm

Always, if enabled

Fluid temperature exceeded

If fluid temperature is too low,

T5B

limits

 

high or low alarm limits for more

return to circulation mode to

 

 

 

than four minutes.

increase fluid temperature.

 

 

 

 

Adjust heater set point if

 

 

 

 

needed.See Heat Fluid section

 

 

 

 

in manual 312359.

 

 

 

 

 

 

 

 

 

If fluid temperature is too high,

 

 

 

 

lower heater set point, and

 

 

 

 

return circulation mode to cool.

 

 

 

 

See Heat Fluid section in man-

 

 

 

 

ual 312359.

 

 

 

 

 

 

 

 

 

Adjust temperature target set-

 

 

 

 

point. See Heat Fluid section in

 

 

 

 

manual 312359.

 

 

 

 

 

P2A

Pressure exceeded advisory

Always, if enabled

Pressure exceeded high or low

Same as P5A or P5B.

P2B

limits

 

advisory limits for more than 15

 

 

 

 

seconds.

 

 

 

 

 

 

T2A

Temperature exceeded tem-

Always, if enabled

Fluid temperature exceeded

Same as T5A or T5B.

T2B

perature limits

 

high or low limits for more than

 

 

 

 

four minutes.

 

 

 

 

 

 

N4D

Pot life timer expired. Mixed

Spray

Have not sprayed enough vol-

Spray fluid, or flush. Resets

 

fluid will cure in hoses, mixer,

 

ume to keep fresh mixed fluid in

when you leave spray mode.

 

and gun.

 

the integration hose, mixer,

See manual 312359. See

 

 

 

whip hose, and spray gun.

Flush, page 14.

 

 

 

 

 

28

313289S

Page 28
Image 28
Graco 313289s important safety instructions Optional User-Settable Spray Limits