Alarms
Alarm |
|
|
|
|
Code | Alarm Problem | When Active | Cause | Solution |
|
|
|
|
|
|
|
|
|
|
|
| Optional |
| |
T5A | Temperature exceeded alarm | Always, if enabled | Fluid temperature exceeded | If fluid temperature is too low, |
T5B | limits |
| high or low alarm limits for more | return to circulation mode to |
|
|
| than four minutes. | increase fluid temperature. |
|
|
|
| Adjust heater set point if |
|
|
|
| needed.See Heat Fluid section |
|
|
|
| in manual 312359. |
|
|
|
|
|
|
|
|
| If fluid temperature is too high, |
|
|
|
| lower heater set point, and |
|
|
|
| return circulation mode to cool. |
|
|
|
| See Heat Fluid section in man- |
|
|
|
| ual 312359. |
|
|
|
|
|
|
|
|
| Adjust temperature target set- |
|
|
|
| point. See Heat Fluid section in |
|
|
|
| manual 312359. |
|
|
|
|
|
P2A | Pressure exceeded advisory | Always, if enabled | Pressure exceeded high or low | Same as P5A or P5B. |
P2B | limits |
| advisory limits for more than 15 |
|
|
|
| seconds. |
|
|
|
|
|
|
T2A | Temperature exceeded tem- | Always, if enabled | Fluid temperature exceeded | Same as T5A or T5B. |
T2B | perature limits |
| high or low limits for more than |
|
|
|
| four minutes. |
|
|
|
|
|
|
N4D | Pot life timer expired. Mixed | Spray | Have not sprayed enough vol- | Spray fluid, or flush. Resets |
| fluid will cure in hoses, mixer, |
| ume to keep fresh mixed fluid in | when you leave spray mode. |
| and gun. |
| the integration hose, mixer, | See manual 312359. See |
|
|
| whip hose, and spray gun. | Flush, page 14. |
|
|
|
|
|
28 | 313289S |