Flush
14 313289S
Flush

Flush Mixed Material

Flush Mix Manifold

Use Solvent Pump
1. Press to turn off system. Follow Pressure
Relief Procedure, page 12. Engage trigger lock.
Remove spray tip.
2. Close sampling valves (AE, AF) and mix manifold
valves (AH, AJ).
3. Open solvent shutoff valve (AK) at mix manifold.
4. Open solvent pump air control (CB). Pull out and
slowly turn solvent pump air regulator (CG) clock-
wise to increase air pressure. Use lowest possible
pressure.
5. Disengage trigger lock. Hold a metal part of the gun
firmly to a grounded metal pail with a splash guard
in place.Use a pail lid with a hole in it to dispense
through. Be careful to keep fingers away from the
front of the gun. Trigger gun until solvent appears.
6. Engage trigger lock.
4)!
TI1949a TI1948a
AE AF
AJ
AH
AK
r_xm1a00_313289_12f
CG
CB
r_312359_312359_3
TI195oa
TI1953a
TI1949a