MODEL 6081-P pH/ORP

SECTION 1.0

 

DESCRIPTION AND SPECIFICATIONS

SECTION 1.0

DESCRIPTION AND SPECIFICATIONS

HIGH ACCURACY AND RELIABILITY for monitoring applications

SELF-ORGANIZING NETWORK for high data reliability and network stability

INDUSTRY LEADING WIRELESS SECURITY

COMPATIBLE WITH 1420 WIRELESS GATEWAY and Emerson Process Management WirelessHARTTM networks

EASY TO READ two-line display with easy to use menus

WirelessHART 7 Digital Communications

SMART Sensor Enabled

CONTINUOUS DIAGNOSTICS monitor sensor performance and health

1.1FEATURES AND APPLICATIONS

The Model 6081-P transmitter is ideal for monitoring

management to reduce power consumption and

applications, especially in hard-to-reach or cost-

extend power module life while delivering highly

prohibitive locations. Model 6081-P measures pH and

reliable measurements with rich HART data and diag-

ORP and is compatible with most Rosemount

nostic information. HART digital communication allows

Analytical pH and ORP sensors. The transmitter has a

access to AMS (Asset Management Solutions) for live

rugged, cast aluminum weatherproof and corrosion-

process variables, useful diagnostics and

resistant enclosure (NEMA 4X). The transmitter includes

troubleshooting information.

a two-line 16-character display with simple and intuitive

 

menu screens. Plain language prompts in six (6)

 

local languages guide the user through the pro-

1.2 SPECIFICATIONS - GENERAL

gramming and calibration procedures. Model 6081 is

compatible with non-preamp pH and ORP sensors and

Enclosure: Cast aluminum. NEMA 4X.

SMART pH sensors from Rosemount Analytical.

Dimensions: 6.55” x 5.40” x 5.15” (166mm x 137mm

 

Installation and start-up of the Model 6081-P wireless

x 131mm).

transmitter is simple. Just power the Model 6081-P

Conduit Openings: 3/4” FNPT

and assign it to a wireless network with a Model 1420

Ambient Temperature: 32 to 122°F (0 to 50°C)

Gateway. The unit will auto-locate the most efficient

Storage Temperature: -4 to 158°F (-20 to 70°C)

path to the host and will begin transmitting measurement

 

data immediately via 2.4 GHz wireless communications.

Relative Humidity: 0 to 95% (non-condensing)

The Self-Organizing Network ensures exceptional data

Weight/Shipping Weight: 7 lbs/8 lbs (3.2/3.6 kg)

reliability and network stability. All of Emerson Process

RFI/EMI: EN-61326

Management’s wireless devices employ Encryption,

 

Authentication, Verification, Anti-Jamming and Key

Digital Communications: HART 7 WirelessHART

Management to ensure data transmission and security.

 

Rosemount Analytical devices include intelligent power

 