HYDRA and REGCOM

APPENDIX C

ADDRESS SELECTION

Each Regcom unit on the RS-485 network must be set with a unique network address.

The address is selected using switches 1-5 from the bank of DIP switches on the rear of the unit. The address must correcspond to the DVR channel number that the text is to be associated with.

The address must be set in binary code (see below), SW1 being the “least significant bit”.

Address No.

SW1

SW2

SW3

SW4

SW5

 

 

 

 

 

 

1

ON

OFF

OFF

OFF

OFF

 

 

 

 

 

 

2

OFF

ON

OFF

OFF

OFF

 

 

 

 

 

 

3

ON

ON

OFF

OFF

OFF

 

 

 

 

 

 

4

OFF

OFF

ON

OFF

OFF

 

 

 

 

 

 

5

ON

OFF

ON

OFF

OFF

 

 

 

 

 

 

6

OFF

ON

ON

OFF

OFF

 

 

 

 

 

 

7

ON

ON

ON

OFF

OFF

 

 

 

 

 

 

8

OFF

OFF

OFF

ON

OFF

 

 

 

 

 

 

9

ON

OFF

OFF

ON

OFF

 

 

 

 

 

 

10

OFF

ON

OFF

ON

OFF

 

 

 

 

 

 

11

ON

ON

OFF

ON

OFF

 

 

 

 

 

 

12

OFF

OFF

ON

ON

OFF

 

 

 

 

 

 

13

ON

OFF

ON

ON

OFF

 

 

 

 

 

 

14

OFF

ON

ON

ON

OFF

 

 

 

 

 

 

15

ON

ON

ON

ON

OFF

 

 

 

 

 

 

16

OFF

OFF

OFF

OFF

ON

 

 

 

 

 

 

Table 9C: Address Selection

LED STATUS INDICATION

Status light A illuminates whenever data is sent from the Regcom to the master unit .

Status light B illuminates to indicate the Regcom is correcly connectly connected via the RS-485 network to the master unit.

Figure 3C: Hydra / Regcom Front Panel

Figure 4C: Hydra / Regcom Rear Panel

 

 

VSI-Pro VIDEO SERIAL INTERFACE

61

Page 61
Image 61
AVE VSI-PRO operation manual Hydra / Regcom Front Panel, Hydra / Regcom Rear Panel