HARD ALARM OUTPUT

APPENDIX J

The VSI-Pro provides two open collector transistor alarm outputs to trigger alarming devices. These are Alarm 1 & 2 in the Alarm menu. Upon an Exception, a VSI-Pro can be programmed to trigger a VCR to go to its fastest record time, have a Quad go full screen, home a switcher, trigger a preprogrammed PTZ, or provide visual or audible alarms. The VSI-Pro provides two alarm outputs that are rated at 12VDC @ 20mA maximum.

The following are some basic circuit designs to take advantage of the alarm output option of the VSI-Pro.

5 VDC

12 VDC

470 OHM

LED

Alarm 1 or 2

Output

Internal

To

VSI-Pro

1K OHM

LED

Alarm 1 or 2

Output

Internal

To

VSI-Pro

5 VDC

RELAY SPDT

Internal

To

VSI-Pro

5 VDC

1N4001

Alarm 1 or 2 Output

BUZZER

Alarm 1 or 2

Output

Internal

To

VSI-Pro

Figure 1H: Hard Alarm Output