APPENDIX I

TCPIP 232 ADAPTER

TCPIP 232 ADAPTER

Interfacing the VSI-Pro to the cash register TCP/IP network requires the TCPIP 232 Adapter along with the VSI-Pro. The IP address of the cash register is programmed into the TCPIP 232 Adapter via on-screen programming. The cash register LAN cable is plugged into the adapter and the supplied additonal LAN cable is then plugged into the cash register. Therefore this DOES NOT require an additional network port for the cash register interface or any host programming of a VPN router.

Figure 1H: Front of TCPIP 232 Adapter

Figure 2H: Rear of TCPIP 232 Adapter

WAVE TRANSFORMER

 

 

 

 

DC CABLE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TCPIP 232

VSI-PRO

 

 

RG-59U

 

 

 

 

 

 

 

 

 

 

CASH REGISTER

 

ADAPTER

 

 

 

 

 

 

 

MONITOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RG-59UCAMERA

Figure 3H: VSI-Pro Connections with TCPIP 232 Adapter

The pin-out between the TCPIP 232 Adapter and the VSI-Pro is as follows:

TCPIP (DB-9M)

VSI-Pro (DB-9M)

RXD 2

 

 

 

3 TXD

TXD 3

 

 

 

2 RXD

GND 5

 

 

 

5 GND

Figure 4H: Pin-Out for TCPIP 232 Adapter to VSI-Pro