Appendices 83

Table C.1: CPS Appliance Enterprise Traps (Continued)

Trap

Description and Variable(s)

 

 

userAuthentication

A user failed to authenticate with the CPS appliance.

Failure

Variable: username.

 

 

 

The CPS appliance has received a command to set itself to factory default values.

factoryDefaultsSet

(The appliance sends this trap after receiving the command, but before actually

 

reverting to factory default values.)

 

 

portAlert

The CPS appliance detected a port alert string on a serial port.

Variables: server name, port number and port alert string.

 

 

 

configurationFile

The CPS appliance has loaded a configuration file. This trap applies to

DSView software.

Loaded

Variables: command issued by username and name of loaded file.

 

 

 

userDatabaseFile

The CPS appliance has loaded a user database file. This trap applies to

DSView software.

Loaded

Variables: command issued by username and name of loaded file.

 

 

 

 

The CPS appliance detected that a port’s power on/off control signal is in the state

powerOnDetected

indicating power is on. This trap is sent upon initialization if the condition is detected.

Subsequent traps are sent only if this signal changes state.

 

 

Variables: server name and port number.

 

 

 

The CPS appliance detected that a port’s power on/off control signal is in the state

powerOffDetected

indicating power is off. This trap is sent upon initialization if the condition is detected.

Subsequent traps are sent only if this signal changes state.

 

 

Variables: server name and port number.

 

 

 

An SPC device is online. This trap is sent upon initialization of the SPC device if it is

SPCOnline

online and responding. Subsequent traps are sent if the SPC device changes from

offline to online.

 

 

Variables: SPC location name and CPS appliance port number.

 

 

 

An SPC device is offline. This trap is sent upon initialization of the SPC device if it is

SPCOffline

not responding. Subsequent traps are sent if the SPC device changes from online

to offline.

 

 

Variables: SPC location name and CPS appliance port number.

 

 

 

An SPC device has a login error. This occurs when the appliance is unable to log in

SPCLoginError

to the SPC device using the username configured in the appliance.

Variables: SPC location name, CPS appliance port number, username attempting to

 

 

log in.

 

 

SPCSocketOn

The On command was issued to an SPC socket.

Variables: command issued by username, server name, SPC location name, CPS

Command

appliance port number and SPC socket number.

 

 

 

SpcSocketOff

The Off command was issued to an SPC socket.

Variables: command issued by username, server name, SPC location name, CPS

Command

appliance port number and SPC socket number.