Appendices 83
Table C.1: CPS Appliance Enterprise Traps (Continued)
Trap | Description and Variable(s) | |
|
| |
userAuthentication | A user failed to authenticate with the CPS appliance. | |
Failure | Variable: username. | |
|
| |
| The CPS appliance has received a command to set itself to factory default values. | |
factoryDefaultsSet | (The appliance sends this trap after receiving the command, but before actually | |
| reverting to factory default values.) | |
|
| |
portAlert | The CPS appliance detected a port alert string on a serial port. | |
Variables: server name, port number and port alert string. | ||
| ||
|
| |
configurationFile | The CPS appliance has loaded a configuration file. This trap applies to | |
DSView software. | ||
Loaded | ||
Variables: command issued by username and name of loaded file. | ||
| ||
|
| |
userDatabaseFile | The CPS appliance has loaded a user database file. This trap applies to | |
DSView software. | ||
Loaded | ||
Variables: command issued by username and name of loaded file. | ||
| ||
|
| |
| The CPS appliance detected that a port’s power on/off control signal is in the state | |
powerOnDetected | indicating power is on. This trap is sent upon initialization if the condition is detected. | |
Subsequent traps are sent only if this signal changes state. | ||
| ||
| Variables: server name and port number. | |
|
| |
| The CPS appliance detected that a port’s power on/off control signal is in the state | |
powerOffDetected | indicating power is off. This trap is sent upon initialization if the condition is detected. | |
Subsequent traps are sent only if this signal changes state. | ||
| ||
| Variables: server name and port number. | |
|
| |
| An SPC device is online. This trap is sent upon initialization of the SPC device if it is | |
SPCOnline | online and responding. Subsequent traps are sent if the SPC device changes from | |
offline to online. | ||
| ||
| Variables: SPC location name and CPS appliance port number. | |
|
| |
| An SPC device is offline. This trap is sent upon initialization of the SPC device if it is | |
SPCOffline | not responding. Subsequent traps are sent if the SPC device changes from online | |
to offline. | ||
| ||
| Variables: SPC location name and CPS appliance port number. | |
|
| |
| An SPC device has a login error. This occurs when the appliance is unable to log in | |
SPCLoginError | to the SPC device using the username configured in the appliance. | |
Variables: SPC location name, CPS appliance port number, username attempting to | ||
| ||
| log in. | |
|
| |
SPCSocketOn | The On command was issued to an SPC socket. | |
Variables: command issued by username, server name, SPC location name, CPS | ||
Command | ||
appliance port number and SPC socket number. | ||
| ||
|
| |
SpcSocketOff | The Off command was issued to an SPC socket. | |
Variables: command issued by username, server name, SPC location name, CPS | ||
Command | ||
appliance port number and SPC socket number. | ||
| ||
|
|