70CPS Installer/User Guide

Table 5.35: SPC Command Parameters (Continued)

ParameterDescription

Minimum amount of time that a socket will stay on before it may be turned off. The value may be specified with S for seconds, M for minutes or H for hour. Valid values are:

ONMIN=<time> 0S, 15S, 30S, 45S, 60S, 75S, 90S, 105S. 1M, 2M, 3M, 4M, 5M, 10M, 15M, 30M, 60M.

1H.

Default = 0S

Minimum amount of time that a socket will stay off before it may be turned on. The value may be specified with S for seconds, M for minutes or H for hour. Valid values are:

OFFMIN=<time> 0S, 15S, 30S, 45S, 60S, 75S, 90S, 105S. 1M, 2M, 3M, 4M, 5M, 10M, 15M, 30M, 60M.

1H.

Default = 0S

User Commands

The User command has several forms, as listed in Table 5.36.

Table 5.36: User Command Summary

Command

Description

 

 

User Add

Adds a new user to the user database.

 

 

User Delete

Deletes a user from the user database.

 

 

User Logout

Terminates a user’s active session.

 

 

User Set

Changes a user’s configuration information.

 

 

User Unlock

Unlocks a locked-out user.

 

 

User Add command

The User Add command adds a new user to the CPS user database. The user database holds a maximum of 64 user definitions. For more information, see Managing User Accounts on page 22 and Access rights and levels on page 23.

Access right: USER

Access level: ADMIN or APPLIANCEADMIN

Syntax

USER ADD <username> [PASSWORD=<pwd>] [SSHKEY=<keyfile>] [FTPIP=<ftpadd>] [KEY=<sshkey>] [ACCESS=<access>] [PREEMPT=1234]