84CPS Installer/User Guide

Table C.1: CPS Appliance Enterprise Traps (Continued)

Trap

Description and Variable(s)

 

 

SPCSocketReboot

The Reboot command was issued to an SPC socket.

Variables: command issued by username, server name, SPC location name, CPS

Command

appliance port number and SPC socket number.

 

 

 

SPCSocketOnSense

An SPC socket encountered an on sense failure.

Variables: server name, SPC location name, CPS appliance port number and SPC

Failure

socket number.

 

 

 

SPCSocketOffSense

An SPC socket encountered an off sense failure.

Variables: server name, SPC location name, CPS appliance port number and SPC

Failure

socket number.

 

 

 

SPCTotalLoadHigh

The SPC device has exceeded the total load maximum threshold.

Variables: SPC location name and CPS appliance port number.

 

 

 

SPCTotalLoadLow

The SPC device exceeded the total load minimum load threshold.

Variables: SPC location name and CPS appliance port number.

 

 

 

 

An SPC socket’s state changed to ‘on.’

SPCSocketStatusOn

Variables: server name, SPC location name, CPS appliance port number and SPC

 

socket number.

 

 

 

An SPC socket’s state changed to ‘off.’

SPCSocketStatusOff

Variables: server name, SPC location name, CPS appliance port number and SPC

 

socket number.

 

 

userLocked

A user account has been locked.

Variables: client IP address, locked username and reason.

 

 

 

 

A user account has been unlocked.

userUnlocked

Variables: client IP address, command issued by username, unlocked username

 

and reason.

 

 

 

The status of one or more servers (connections paths) has changed. The appliance

aggregatedServer

always sends this trap upon bootup. Thereafter, it sends the trap when there is a

change in connection path status, and will include only those paths whose status

StatusChg

has changed.

 

 

Variable(s): connection path(s)