Resetting to the Factory Default Settings

To reset the AXIS 206 to the original factory default settings, go to the System Options > Maintenance web page, or use the Control button on the rear of the camera (see the illustration on page 7) as described below:

Using the Control Button

To reset the AXIS 206 to the factory default settings using the Control Button:

1.Disconnect the power adapter.

2.Press and hold the Control button while reconnecting the power.

3.Keep the Control button pressed until the Status Indicator displays amber (this may take up to 15 seconds).

4.Release the Control button.

5.When the Status Indicator changes to Green (which may take up to 1 minute), the process is complete and the AXIS 206 has been reset. The unit will now have the default IP address 192.168.0.90