change:
displayed.

Configuring the MES1A/B

12.To change the parameter, type in a new value, then press Enter. If you wish to leave the parameter as it was, simply press Enter. A prompt for the next parameter will appear.

13.When all parameters in the currently selected section are complete you will again be prompted to select a menu item. Select another section and continue the configuration process.

Saving Configuration Settings

When all categories have been configured you must save your configuration to the MES1A/B.

To Save the configuration settings to the MES1A/B, at the Select Command or parameter set (1..4) to change: prompt type S.

Quitting Without Saving

To Quit the configuration session without saving, type Q. The background color will change to gray and the MES1A/B will re-start without updating the configuration settings.

Reconfiguring to Factory Settings

The MES1A and MES1B come from the factory preconfigured for correct operation with their respective interfaces. The following procedure describes how you can return the MES1A and MES1B to their original factory settings.

To Reconfigure the MES1A to Factory Settings:

Type D at the Select Command or parameter set (1..4) to prompt. The Configuration Menu is updated with the new settings

To Reconfigure the MES1B, to Factory Settings:

14.Type D at the Select Command or parameter set (1..4) to change: prompt.

15.Type 2 to enter the Serial & Mode Settings section and set the Serial Mode for RS-485Two-Wire(see the next section for details).

Manual Documentation Number: MES1A/MES1B-2106m

PN7138-rev001

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104www.bb-elec.com