Programming

Voltage

<0.05% + 10mV

 

 

Accuracy, 12months,

 

 

(@ 25 °C ± 5 °C)

 

 

±(% of output+offset)

Current

<0.2% +10mA

 

 

 

 

Readback Accuracy

Voltage

<0.05%+15mV(<20V),

<0.05%+120mV(20V)=

 

12months,

 

 

(25 °C ± 5 °C)

 

 

 

 

±(% of output+offset)

Current

<0.1% +15mA

 

 

 

 

Ripple

Voltage

1mVrms/3mVp=-p

 

 

(20Hz ~20MHz)

Current

5mArms

 

 

 

 

Temperature

Voltage

<0.02%+5mV

 

 

Coefficient,

 

 

(0 °C ~ 40 °C)

 

 

±(% of output+offset)

Current

<0.1% +5mA

 

 

 

 

Readback

Voltage

<0.02%+15mV(<20V),

<0.02%+120mV(20V)=

 

Yemperature,

 

 

Coefficient,

 

 

 

 

±(% of output+offset)

Current

<0.1% +15mA

 

 

 

 

2.2 Supplemental Characteristics

State Storage Memory

Sixteen (16) user-configurable stored states

Recommended Calibration Interval

1 year

AC Input Ratings (selectable via switch on the rear panel)

Option OP1: 220VAC ± 10%, 47 to 63 Hz

Option OP2: 110 VAC ± 10%, 47 to 63 Hz

Maximum input power

350VA

Cooling

Fan cooled

Operating Temperature

32 to 104 °F (0 to 40 °C) for full rated output

Storage Temperature

-68 to 158 °F (-20 to 70 °C) for storage environment.

13