THE BADGER®-RADIX®User Guide

February 2007

Find on Wrong

This setting pertains only to touch

This setting is very handy for

 

meter reading. The gathered meter

touch meter reading because

 

reading information contains the

it allows you to read meters

 

module ID number. If the number

out of the normal reading

 

is different than the ID number for

sequence. If you need to

 

the current meter on the read screen

resequence the route, using

 

(the meter was read out of

this setting you can read the

 

sequence), the Badger-Radix will

route in the new reading

 

search for the correct meter if this

sequence order with ease.

 

setting is chosen. If the setting is

You can then resequence the

 

not chosen, the Badger-Radix will

route using the new read

 

alert you to the fact that the reading

date/times.

 

indicates that the wrong meter is

 

 

being read.

 

Run Consumption

Not used at this time

Not used at this time

Auto Clear

This setting is used with older

This setting is not used within

Tamper

technology radio systems.

the Badger-Radix.

Verification

When this setting is chosen, the

If you are required by state

 

Badger-Radix will request a manual

law to periodically verify an

 

reading for each successful reading.

interrogated meter reading

 

This manual verification of the

with a visual reading, the

 

interrogated reading can be used to

Badger-Radix will request

 

satisfy requirements in some states.

your required visual reading

 

 

when this setting is chosen.

Show Previous

This setting (as well as Show High

To insure accuracy of the meter

Reading

and Low) controls the amount of

readings, some utilities will

 

information available to the meter

choose to clear this setting.

 

reader. When this setting is chosen,

Other utilities will choose this

 

the previous reading value is

setting so that if an

 

displayed when the View High/Low

investigation on the operation

 

button is pressed.

of the meter is needed, this

 

 

information is available. You

 

 

need to determine which option

 

 

is right for you.

Hi / Low

This setting allows you to choose how

If you use the last meter

Readings Fail

the high and low limits are used in the

reading as the low limit and

 

Badger-Radix. If the setting is

you wish to be alerted to

 

checked, the Badger-Radix will label a

conditions of no usage, check

 

reading as High if the reading is

this setting. Note that the

 

greater than or equal to the high limit.

high and low limit checking

 

Similarly, the reading will be labeled

is only in the Badger-Radix.

 

low if the value is less than or equal to

It does not extend to Badger

 

the low limit. When the setting is

CONNECT.

 

unchecked, the high and low

 

 

processing is strictly greater than the

 

 

high limit or less than the low limit.

 