138 LED-PRO • User’s Guide
_K==oÉãçíÉ=`çåíêçä=mêçíçÅçä
LED-PRO Remote Commands
•Query:
ICPHO? in
Returns the Input Clock Phase Offset in the format
= nn
SCPHO 1 15 (Adjusts Input clock phase offset manually to 15 on input 1.)
SCPHO? 1 (Queries the Input clock phase offset of channel 1.)
f`ifpq
•Description: Lists the names of all saved Input configurations.
•Parameters: None
•Returns: List the names of saved Input configurations, one name per line.
SICLIST (Lists all saved Input configurations.)
f`abi=ÑáäÉå~ãÉ=
•Description: Delete saved Input configuration.
•Parameters:filename - name of configuration to be deleted (not case sensitive).
SICDEL file1 (Deletes Input configuration stored as FILE1.)
f`ob`=áå=ÑáäÉå~ãÉ
•Description: Recalls saved Input Configuration.
•Parameters:
in - Input chnl [1-4]
filename - configuration that is being recalled (not case sensitive).
SICREC 3 file1 (Recalls Input configuration stored as file1 for channel 3.)
f`opq=áå
•Description: Reset Input Configuration for the specified channel.
•Parameters: in - Input chnl [1-4]
SICRST 1 (Resets Input Configuration for channel 1)
f`p^s=áå=ÑáäÉå~ãÉ
•Description: Saves Input configuration to non-volatile memory.
•Parameters:
filename - name given to configuration when it is stored. This filename is
translated to all upper case characters. If same input configuration name
exist, it will be overwritten.
in - Input chnl [1-4]
SICSAV 3 file1 (saves Input configuration as FILE1 for channel 3.)