Random Access Adjustment Mode

The file name will be displayed in the upper right corner. The following items can be adjusted :

Total quantity horizontal pixels Active quantity horizontal pixels Horizontal start in pixels

Horizontal period in µs (is automatically adapted during the installation of a file with LOAD) Total vertical lines (is automatically adapted during the installation of a file with LOAD) Active vertical lines

Vertical start in lines

Interlaced : toggle on/off (is automatically set to its correct position during the installation of a file with LOAD)

 

 

EDIT FILE

xga.s30

HORIZONTAL

 

 

 

TOTAL

 

 

1344 PIXELS

ACTIVE

 

 

1024 PIXELS

S T A R T

 

 

296

PIXELS

PERIOD

 

 

20.678 µS

VERTICAL (FIELD)

 

 

TOTAL

 

 

806

LINES

ACTIVE

 

 

768

LINES

S T A R T

 

 

36 LINES

INTERLACED

 

[OFF]

READ AMDS

 

 

 

OPTIONS

 

 

 

,

,

,

<ENTER>, <EXIT>

All settings can individually be changed.

1Push the cursor key or to select an item.

The color of the selected item will change and follow one of the three methods to change the value.

a. method 1:

1press ENTER to activate the digits

2enter directly with the numeric keys on the RCU or local keypad the new value or

b. method 2:

1Press ENTER to activate the digits

2Push the cursor key or to select the changing digit.

3 Push the cursor key or to scroll to desired digit.

4 When finished press ENTER to confirm.

c. method 3

1Counting up or down by pushing the cursor key or .

How to find the correct values for the displayed item?

During the installation of a file with LOAD, the horizontal period, the total number of vertical lines and the interlaced mode are automatically measured and filled in in the menu table. These values will be available when starting up the EDIT procedure of an active file.

(Caution : Do not adjust these settings on an active file, they are used to identify the input source file.)

If the value for "Horizontal Total Pixels" is wrong, sampling mistakes (small vertical bars in the projected image) will be seen in the image. Select "Total" and adjust the pixel quantity. Adjust for zero bars (hint: if the number of bars increase, adjust in the other direction).

The "Active Pixels" : determine the width of the window on the screen. This value is normally given in the source specifications. If not, adjust until full image is displayed (no missing pixels).

"Horizontal Start" : number of pixels between the beginning of the input signal and the start of the video information in the signal.

"Horizontal Period" : already filled in with the correct value when active file. (see caution above).

The "Vertical Total Lines" are already filled when an active file is selected to be edited (see caution above).

The "Active Lines" : number of horizontal lines determining the height of the projected image. This value is normally given in the specification of the source. If not, adjust until full image height is displayed (no missing lines)

Vertical start : number of lines between the start of the input signal and start of the image on the screen.

Interlaced [On] or [Off] : this selection is automatically filled when active file has to be edited. If the image is wrong due to mismeasurement, use the ENTER key to toggle between [On] and [Off]. (for interlaced images, 1 frame contains 2 fields).

Read AMDS

AMDS = automatic mode detection & synchronisation

During the installation of a file with LOAD, the system automatically measured the horizontal period, the total vertical lines and the interlaced mode.

When selecting Read AMDS, the system remeasures the above indicated items.

Options

Source Number : The source number of a non-active source can be changed to any other source number. This makes it possible to create a file for future source numbers.

Clamp Position : Clamping determines the black level of the signal.

The clamp pulse can be related to the leading or the trailing edge of the sync pulse. Use the ENTER key to toggle between [leading] and [trailing].

Clamp Delay : The time between the leading edge of the clamp pulse and the locked edge of the sync pulse.

Can be any value between 0 and 255. Change the value by pushing the cursor key or .

5976052 BARCOREALITY 9300 070999

 

 

EDIT FILE OPTIONS

Source number

 

1

Clamp

position

 

[leading]

Clamp

delay

 

0

Clamp

width

 

10

Field

polarity

 

[pos]

Field

select

 

[both]

Vertical

refresh

 

[sync]

Vert. sync

polarity

 

[leading]

 

 

 

Select with

or

 

 

<ENTER>

to

toggle

 

 

or

to change value

 

 

 

<EXIT>

to

return

 

 

 

 

 

8-3

Page 33
Image 33
Barco R9001560 manual How to find the correct values for the displayed item?, Read Amds, Options